HomeBlogTypes of Check Valves and How to Select the Right Design

Types of Check Valves and How to Select the Right Design

November 17, 20267 min read
Types of Check Valves and How to Select the Right Design

Valves are manufactured in such a way that they only allow flow in one direction and prevent the backflow of fluid through the pipes used in industries. The valves have varied closures depending on how the valves respond to changes in pressure and flow reversal EuroValve Italia offers different check valve designs for industrial applications. 

There are many types of check valves available, and choosing the right type of valve should be based on certain factors.

How Check Valves Prevent Reverse Flow?

In contrast to manual operation isolation valves, check valves automatically react to changes in flow rate and differential pressure.

The swing check valve employs a hinged disk that swings with the direction of forward flow, whereas the spring-loaded axial flow check valve utilizes a closure member that is guided to react to decreasing forward flow. Their closing characteristics can differ significantly.

The closure behaviour can also vary according to the valve design, installation orientation, spring assistance and flow conditions. These factors influence how quickly the closure element responds when forward flow decreases or reverses.

Main Check Valve Designs:

Each check valve construction has a different closure movement and installation profile.

Check Valve Type

How It Works

Key Selection Considerations

Typical Application

Swing Check Valve

Hinged disc opens with forward flow and returns toward the seat

Requires sufficient space for disc movement; closing response depends on flow conditions and orientation

General pipelines, process and utility systems

Dual Plate Check Valve

Two spring-assisted plates open and close within a compact body

Compact wafer-style construction; short closing travel; installation orientation and flow conditions should be checked

Compact pipeline and process installations

Lift Check Valve

Guided disc lifts from the seat under forward differential pressure

Requires suitable orientation and sufficient differential pressure for opening; guided closure affects pressure loss and response

Process, steam and higher-pressure piping

Tilting Disc Check Valve

Pivoted disc uses a shorter movement than conventional swing designs

Shorter disc travel can provide a faster closing response under suitable flow conditions

Pipeline and process applications

Axial Flow Check Valve

Guided closure element moves along the pipeline axis

Inline flow path and closing response should be considered together with flow velocity and differential pressure

Oil and gas, process and critical flow systems

Swing Check Valve for General Pipeline Service:

A swing check valve uses a hinged disc that opens when forward flow develops. As the flow falls or reverses, the disc moves back toward the seat.

This construction is suitable for many general pipeline, process and utility applications. It can be used where the installation allows sufficient space for the disc movement.

The closing response depends on the flow conditions, valve orientation and system dynamics. These factors should be considered when a rapid response to flow reversal is important.

Compact Dual Plate Check Valve Design:

In a dual plate check valve, there are two spring-loaded plates instead of the traditional disc hinge.

The plates require minimal closing stroke making the valve suitable for installations in small spaces. It therefore becomes appropriate to use a dual plate valve in situations where the installation space length and weight is important.

Its spring-loaded closure mechanism may react promptly when the forward flow is reduced. Nevertheless, the closing characteristics of the valve depend on the design of the valve and the system dynamics. The entire piping system therefore needs to be analyzed where slamming during reverse flow is an issue.

Before selecting a dual plate valve, the installation orientation, flow speed, differential pressure, pressure loss tolerance and piping space are to be verified.

Lift and Axial Flow Designs:

A lift check valve uses a guided closure element that moves vertically from the seat when forward differential pressure is sufficient. It can be used in process, steam and higher-pressure piping.

An axial flow check valve operates with an inline closure mechanism that keeps the flow path aligned with the pipeline. The guided closure can respond as forward flow decreases, making flow velocity and differential pressure important selection factors.

Both designs should be evaluated according to the required closing response, pressure drop, installation orientation and process conditions.

Tilting Disc Check Valves:

A tilting disc check valve uses a pivoted disc that requires less travel than a conventional swing arrangement.

The shorter movement can provide a faster closing response under suitable operating conditions. It is used in pipeline and process applications where the dynamic behaviour of the closure element is an important consideration.

The expected closing response should be evaluated together with flow velocity, differential pressure and overall system dynamics.

Non-Slam Behaviour and Reverse-Flow Protection:

The design of some check valves incorporates a spring or guided closing action that ensures prompt closing when the flow rate forward becomes less.

Designs of non-slam check valves may help in avoiding pressure surges caused by reverse flow, but only if the valve is appropriately selected for the particular system.

When there are issues such as water hammer or reverse flow, the whole pipe line needs to be taken into consideration.

Materials, Pressure Classes and Connections:

The valve body and internal components need to be compatible with the process medium, pressure, temperature and corrosion environment.

Technical Parameter

Available Options / Grades

Body construction

Cast steel, forged steel

Carbon steel

ASTM A216 WCB, ASTM A105/A105N, EN 1.0619

Low-temperature steel

ASTM A352 LCB/LCC, ASTM A350 LF2

Stainless steel

304/304L, 316/316L, CF8, CF8M, CF3, CF3M

Duplex stainless steel

Duplex 2205, ASTM A182 F51/F60, UNS S31803/S32205

Super Duplex

ASTM A182 F53/F55, UNS S32750/S32760

Nickel alloys

Monel 400, Inconel 625, Hastelloy C276

Titanium

Titanium Grade 2 / UNS R50400

Seating

Metal seated, soft seated

Pressure rating

PN and ASME Class ratings according to construction

End connections

RF flange, RTJ, wafer, lug, butt weld, socket weld, threaded

Standards

EN 16767, API 594, API 602, ASME B16.34, API 598

The disc, plates, hinge, pins, springs and seats may require separate material specifications, particularly for corrosive, seawater or demanding process services.

Flow Conditions and Installation:

Check valve selection cannot consider pipeline size alone.

Flow velocity, differential pressure and pressure drop may affect the performance of the closure element. Valve orientation must also be considered since some valves rely on gravity, spring action or guided closure in order to operate correctly.

The correct type of end connection must be selected to suit the piping system. There are flanged, wafer, lug, welded and threaded connections that can be used based on the design of the valve.

Face-to-face measurements should also be compared with the piping arrangement before installation.

Check Valve Selection for Different Applications:

The right check valve selection starts with the service conditions.

Consider:

  • Process medium

  • DN/NPS size

  • Operating and design pressure

  • Operating temperature

  • Flow velocity

  • Differential pressure

  • Allowable pressure drop

  • Installation orientation

  • Required closing response

  • Material compatibility

  • End connection

A swing check valve can be suitable for general pipeline service where sufficient space is available for disc movement. A dual plate check valve may be considered where compact construction and short closing travel are important.

A lift check valve can be considered for process, steam and higher-pressure piping where guided closure is suitable. Tilting disc designs offer different closing characteristics from conventional swing arrangements, while axial flow designs can be considered where an inline closure mechanism and specific flow characteristics are required.

The selection should also consider whether the valve needs spring-assisted closing, the expected flow reversal behaviour and the allowable pressure drop.

Standards and Testing:

Check valves may be designed and tested according to standards applicable to their construction and service.

EN 16767 applies to metallic check valves. API 594 applies to flanged, lug, wafer and butt-welded check valves, while API 602 applies to small forged valves. ASME B16.34 addresses valve design and temperature-pressure requirements.

Dimensional and connection standards that apply include EN 558, ASME B16.10, EN 1092-1 and ASME B16.5. Pressure and inspection testing can be carried out according to EN 12266-1 or API 598, as applicable.

Selecting the Check Valve for the System:

The right check valve depends on the required closing behaviour, available installation space and operating conditions.

  • Swing check valves: Consider for general pipeline service where sufficient space for disc movement is available.

  • Dual plate check valves: Consider where compact construction and short closing travel are important.

  • Lift check valves: Consider where guided closure is suitable for the flow conditions and installation orientation.

  • Tilting disc check valves: Evaluate where the disc's shorter travel and closing characteristics suit the application.

  • Axial flow check valves: Consider where a guided, inline closure mechanism meets the system's flow and pressure requirements.

The final choice should be based on the valve's design specifications and the requirements of the piping system.



Expert Valve Guidance
Need Help Specifying the Right Valve?

Our Italian engineering team provides custom valve selection, technical drawings, and project-specific quotes within 24 hours.

Contact Our Engineers